<< Click to Display Table of Contents >> Min./Max. Temperature Style |
This style is used when you are working with the Min./Max. Temperature tool.
Name |
Here, you define the name of the style. You cannot leave this field empty; the chosen name must be unique, i.e. not identical to another existing name. Aside from these limitations, you are free to choose any name. |
Digits |
Number of decimal places or significant digits, which are to be displayed. The kind - Decimal Points or Significant - you can select using the adjacent drop down-list. |
Thousands delimiter |
The digits left of the decimal point will be grouped into thousands. |
Show units |
The appropriate units will be shown after each numerical value. The units can be adjusted in the Units tab of the Options dialog window. |
Show result symbol |
The appropriate symbols (dependent on the type of value) will be shown before each numerical value. |
Style |
Here, you determine whether the label line should be a simple or an orthogonal (right-angle bent) line. |
Line |
This setting group determines the properties of label lines (color, style, size and type). Note that some of the lines cannot be shown when their thickness exceeds 0.394 mm. |
End Point Markers |
Here, you can determine how the end of both label lines should look like. There are two drop down lists that show the different possibilities. |
Temperature |
If this option is activated, the minimal surface temperature is displayed. At least one option of the group "Shown Properties" has to be selected. |
fRSi-Value |
If this option is activated, the fRSi-factor is shown additionally to the minimal surface temperature. At least one option of the group "Shown Properties" has to be selected. |
Surface humidity |
If this option is activated, the surface humidity is shown additionally to the minimal surface temperature. At least one option of the group "Shown Properties" has to be selected. |
Room humidity for condensation |
If this option is activated, the room humidity for condensation is shown additionally to the minimal surface temperature. At least one option of the group "Shown Properties" has to be selected. |
Room humidity for moisture |
If this option is activated, the room humidity for moisture is shown additionally to the minimal surface temperature. At least one Option of the group "Shown Properties" has to be selected. |
Condensation zone |
If this option is activated, a condensation zone will be displayed with a unique line style - only if a condensation zone is present. The properties of the polyline you can adapt in the setting group line properties (Of: Condensation zone). |
Moisture zone |
If this option is activated, zones where the surface humidity exceed the critical humidity will be displayed with a unique line style - only if this zone is present. The properties of the polyline you can adapt in the setting group line properties (Of: Moisture zone). The critical surface humidity you can define in the Properties flyout of the min./max. temperaturobject. |
Maximum temperature |
If this option is activated then the maximum temperature is shown next to the minimum temperature. |
Average temperature |
If this option is activated then the average temperature will be shown next to the minimum temperature. |
Line properties |
This setting group determines the properties of the surface edge line, the condensation zone and the moisture zone (color, style, size and type). The line kind you can select using the Of: drop down-list. Note that some of the lines cannot be shown when their thickness exceeds 0.394 mm. |