Various Warnings

<< Click to Display Table of Contents >>

Navigation:  Reference > Dialog Windows > Various Dialog Windows >

Various Warnings

Previous pageReturn to chapter overviewNext page

In this chapter, we shall discuss various warning dialogs:

Importing Database Entries - Existing Entries
Importing Database Entries - Invalid Entries
Calculation - Critical Material present
Calculation - Radiation Properties
Calculation - Automatic Cavity Subdivision

Importing Database Entries - Existing Entries

A material with the same name already exists in the materials database.

Fields

Change

Opens a dialog window in which a new name can be defined.

Change All

All names in conflict are automatically changed. All names are now unique.

Skip

Skips this entry without importing the data.

Skip All

Skips over all materials with names matching the database without further warning.

Cancel

Cancels the import process

Importing Database Entries - Invalid Entries

The definition of the listed material is either incomplete or invalid.

Fields

Skip

Skips this entry and continues with the importing.

Cancels

Cancels the import process

Calculation - Critical Material present

In the Special Materials Options dialog window you have defined materials as critical, which are visible in the construction.

Fields

Stop

The calculation is stopped and all domains with critical materials are highlighted.

By repeatedly clicking on the "Zoom In" button in the message line, all critical material domains will be highlighted in order to assign other materials to these domains.

These highlights will disappear in the next calculation.

Continue

The calculation continues with the present values.

,
Calculation - Radiation Properties

In the file are cavity materials according to EN ISO 10077-2 that don't match with the option settings (cf. Option dialog window).

Fields

Stop

The calculation is stopped and all cavities whose properties don't match with the options will be highlighted.

By repeatedly clicking on the "Zoom In" button in the  message line, all critical material domains will be highlighted in order to assign other materials respectively radiation properties to these domains.

These highlights will disappear in the next calculation.

Continue

The calculation continues with the current subdivisions.

 

,
Calculation - Automatic Cavity Subdivision

You have selected the option "automatic subdivision of domains according to EN ISO 10077-2" in the Option dialog window. Not all of the domains could get subdivided.

Fields

Stop

The calculation has stopped and all necks will be highlighted where the cavities may be subdivided according to standard EN ISO 10077-2.

By repeatedly clicking on the "Zoom In" button in the message bar, all highlighted necks will be shown step-by-step in order to subdivide them manually using the Cut tool.

The markers will only disappear after the next calculation.

Continue

The calculation continues with the current subdivisions.